spinwhe.blogg.se

How to open trnsys file on matlab
How to open trnsys file on matlab











In established GSHP systems, high-performance GHEs result in lower CO 2 emissions and less electrical load on the power grid. Ground heat exchangers (GHEs) are an emerging technology, which are an important component of GSHP systems for extracting ground heat during the heating season and injecting absorbed dwelling heat into the ground during the cooling season. In recent years, many GSHP systems have been developed and installed because of their environmentally friendly performance and high efficiency. The ground can be used as a heat source or sink to meet the needs of ground source heat pump (GSHP) systems for heating and cooling of building spaces. IntroductionĬompared with outdoor air, the ground retains a relatively stable temperature because of its large heat mass. It provides a method for the design of a solar collector area which needs to be determined in the seasonal heat storage solar ground source heat pump system.

how to open trnsys file on matlab

The optimized system could maintain a higher annual average COP because of the steady soil temperature. After the system is optimized, the solar collector area increases of 20% in the Beijing region, 25% in the Harbin region, and 15% in the Zhengzhou region could help to maintain the annual average soil temperature balance. Long-term operation will test the matching rate of the compensation system with the conventional GSHP system. Design parameters such as the solar collector size are optimized for the building load and average soil temperature in various cold regions. Moreover, the simulation data show that the soil temperature would still be decreasing if based on the previous solar energy area calculation method. Because of the soil temperature decrease, the minimum heating coefficient of performance (COP) values decrease by 23%, 46%, and 11% over the ten years for GSHP operation in these three regions, respectively. The annual average soil temperature decreases 7.3☌, 11.0☌, and 5.3☌ during ten years of conventional GSHP operation in the Beijing, Harbin, and Zhengzhou regions, respectively.

how to open trnsys file on matlab

The simulation results showed that the imbalance efficiencies in the Beijing, Harbin, and Zhengzhou regions are 55%, 79%, and 38%, respectively. System performance was simulated over periods of ten years. The Beijing, Harbin, and Zhengzhou regions were used in numerical simulations to represent three typical cities where buildings require space heating (a cold region, a severe cold region, and a hot summer and cold winter region, respectively).

how to open trnsys file on matlab

A ground source heat pump (GSHP) project was established using the transient system simulation program (TRNSYS) based on a ground heat exchange theoretical model, which was validated by a previously established experiment in Beijing. This paper presents the design and optimization of a solar-assisted storage system to solve this issue. The cold accumulation problem can lead to performance degradation of heat pumps.













How to open trnsys file on matlab